Safety glasses or safety goggles sr hearing protection ear canal.
Arc rated clothing table.
Incident energy exposures equal to 1 2 cal cm 2 up to 12 cal cm 2.
This table is new in nfpa 70e 2018 but the same as h 3 in the non mandatory annex for years and would guide you to choose a face.
Such logos and name tags may violate 1910 269 l 8 iii l 8 iv or l 8 v.
Arc flash ppe category 1.
Table 130 5 g selection of arc rated clothing and other ppe when the incident energy analysis method is used.
These fabrics can melt or ignite easily when an electric arc occurs.
Incident energy analysis method is used.
Arc rated clothing minimum arc rating of 4 cal cm 2 a.
Arc rated clothing with an arc rating equal to or greater than the estimated incident energy a long sleeve shirt and pants or coverall or arc flash suit sr.
Arc rated jacket parka rainwear or hard hat liner an protective equipment.
Logos and name tags made from non flame resistant material can adversely affect the arc rating or the flameresistant characteristics of arc rated or flameresistant clothing.
Discover a brief overview of each of the 4 ppe categories including the clothing required for each as well as information on determining which ppe you need to use.
We supply distributors with protective gear for the safety of their workers and the industry.
Nfpa 70e 2018 now gives four categories of ppe with each category including the minimum arc rating value for the required ppe.
Arc rated long sleeve shirt and pants or arc rated coverall.
Incident energy exposure equal to 1 2 cal cm 2 up to 12 cal cm2.
Arc rated safety llc.
New table h 3 b added for guidance on selection of arc rated clothing and other ppe for users who conduct a hazard analysis to determine the incident energy exposure in calories cm2 less than or equal to1 2 cal cm2 greater than 1 2 to 12 cal cm2 greater than 12 cal cm2.
In the 2018 70e the table was modified to eliminate any clothing or ppe under 1 2 cal cm2 because it only deals with arc rated clothing and other ppe.
Arc rated safety specializes in arc flash personal protective clothing and equipment.
Nfpa 70e table 130 5 g selection of arc rated clothing other ppe when the.
When you do an incident energy analysis or an arc flash study the ppe level table 130 5 g selection of arc rated clothing and other ppe when the incident energy analysis method is used gives you guidance.
The table was renamed table 130 5 g and put into the body of the standard.
Aarc rated clothing with an arc rating equal to or greater than the estimated incident energy.
As a result table h 3 b was not being used as intended.